Straight Up Secern +

Rough and versatile high performer

A rough finish that suits various design themes. Take the opportunity to add a colored seamless acoustic ceiling to level up your design game. Easy to clean or repair thanks to our reactivation technology.

Facts

Dimensions & weight

15 mm: 16 mm (5/8 inch) total construction height excl suspension grid. Weight (dry, excl suspension grid/mech. fasteners) 4.85 kg/m² (15.89 oz/ft²).

15 mm: 66 mm (2 19/32 inch) total construction height excl suspension grid. Weight (dry, excl suspension grid/mech. fasteners) 7.35 kg/m² (24.08 oz/ft²).

20 mm: 21 mm (25/32 inch) total construction height excl suspension grid. Weight (dry, excl suspension grid/mech. fasteners) 3.13 kg/m² (15.89 oz/ft²).

20 mm: 70 mm (2 4/5 inch) total construction height excl suspension grid. Weight (dry, excl suspension grid/mech. fasteners) 5.38 kg/m² (24.08 oz/ft²).

25 mm: 26 mm (1 1/32 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 2.78 kg/m² (9.11 oz/ft²).

39 mm: 40 mm (1 37/64 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 4.12 kg/m² (13.51 oz/ft²).

Installation

15 mm-20 mm: Mechanically fasted directly to suspension grid, with or without absorbing backer board. Can be mounted on walls or ceilings.

20 mm-70 mm: Can be mounted on walls or ceilings. Can be mounted with no gaps on existing ceilings or wall surfaces, or suspended, mounted on plasterboard. Mechanically fasteners or with adhesive.

Light reflectance
93% per ASTM E147-98A.

Fire safety classification

15 mm (& 66 mm): Class A per ASTM E84, B s1d0 per ISO EN-13501-1:2018

20 mm-70 mm: FSR=0, SDI=0 per ASTM E84 & CAN/ULC S-102, A2 s1d0 per ISO EN-13501-1:2018

Cleaning and repair
Can be vacuumed. Spots can be removed with water and sponge. Damaged surfaces can be repaired.

Color selection
RAL 1001, RAL 7023, RAL 7035, RAL 7039, RAL 9001, RAL 9003 and RAL 9004.
Also available in Standard white.
For other colours contact Styjl.

Environment

15 mm (& 66 mm): CDPH/EHLB Standard method V1.2 2017.

20 mm (& 70 mm):ISO 16000-6:2021 (Indoor air – Part 6:Determination of organic compounds (VVOC, VOC, SVOC)

25 mm-39 mm: 0 g/l (0,00 lbs/gal) VOC (emissions) per ASTM D3960, LEED.

Climate
Installation temperatures should be between 15 °C and 32 °C (60 °F and 90 °F) with humidity that does not exceed 70%. Tested for mold growth per ASTM D3273.

Sound absorption

15 mm (& with backerboard 66 mm): NRC 0.55 – 0.85 per ASTM C423. Alpha W 0.60 (class C)-0.75 (class C) per ISO 354/ISO11654.

20 mm (& with backerboard 70 mm):NRC 0.75 – 0.95 per ASTM C423. Alpha W 0.55 (class D)-0.95 (class A) per ISO 354/ISO11654.

25 mm: NRC 0.85-0.90 per ASTM C423. Alpha W 0.85 (class B)-0.95 (class A) per ISO 354/ISO11654.

39 mm: NRC 0.85-0.90 per ASTM C423. Alpha W 0,90 – 0.95 (class A) per ISO 354/ISO11654.

Ceiling Attenuation Class (CAC)

15 mm with 50 mm backer board: 51 per ASTM E1414.

 

More facts about the product

Styles

Order samples

Sound measurements

Let´s talk

Is it really possible? Yes, where there’s a will there’s a way! Contact us and we will share our experience and help you find your best solution for a fantastic seamless acoustic experience. And of course we are happy to send more information or a product sample if requested.