Styjl » Your vision, our solution » Standard+ » Straight Up Marble
Add a touch of elegance and flair to any interior design with an acoustic ceiling in marble. No worries in procuring the actual marble and no worries about the sound quality or speech intelligibility. All in one, great looks and great sound.
Dimensions & weight
15 mm: 16 mm (5/8 inch) total construction height excl suspension grid. Weight (dry, excl suspension grid/mech. fasteners) 4.85 kg/m² (15.89 oz/ft²).
15 mm: 66 mm (2 19/32 inch) total construction height excl suspension grid. Weight (dry, excl suspension grid/mech. fasteners) 7.35 kg/m² (24.08 oz/ft²).
20 mm: 21 mm (25/32 inch) total construction height excl suspension grid. Weight (dry, excl suspension grid/mech. fasteners) 3.13 kg/m² (15.89 oz/ft²).
20 mm: 70 mm (2 4/5 inch) total construction height excl suspension grid. Weight (dry, excl suspension grid/mech. fasteners) 5.38 kg/m² (24.08 oz/ft²).
25 mm: 26 mm (1 1/32 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 2.78 kg/m² (9.11 oz/ft²).
39 mm: 40 mm (1 37/64 inch) total construction height. Weight (dry, excl adhesive/mech. fasteners) 4.12 kg/m² (13.51 oz/ft²).
Installation
15 mm-20 mm: Mechanically fasted directly to suspension grid, with or without absorbing backer board. Can be mounted on walls or ceilings.
20 mm-70 mm: Can be mounted on walls or ceilings. Can be mounted with no gaps on existing ceilings or wall surfaces, or suspended, mounted on plasterboard. Mechanically fasteners or with adhesive.
Light reflectance
93% per ASTM E147-98A.
Fire safety classification
15 mm (& 66 mm): Class A per ASTM E84, B s1d0 per ISO EN-13501-1:2018
20 mm-70 mm: FSR=0, SDI=0 per ASTM E84 & CAN/ULC S-102, A2 s1d0 per ISO EN-13501-1:2018
Cleaning and repair
Can be vacuumed. Spots can be removed with water and sponge. Damaged surfaces can be repaired.
Environment
15 mm (& 66 mm): CDPH/EHLB Standard method V1.2 2017.
20 mm (& 70 mm):ISO 16000-6:2021 (Indoor air – Part 6:Determination of organic compounds (VVOC, VOC, SVOC)
25 mm-39 mm: 0 g/l (0,00 lbs/gal) VOC (emissions) per ASTM D3960, LEED.
Climate
Installation temperatures should be between 15 °C and 32 °C (60 °F and 90 °F) with humidity that does not exceed 70%. Tested for mold growth per ASTM D3273.
Sound absorption
15 mm (& with backerboard 66 mm): NRC 0.55 – 0.85 per ASTM C423. Alpha W 0.60 (class C)-0.75 (class C) per ISO 354/ISO11654.
20 mm (& with backerboard 70 mm):NRC 0.75 – 0.95 per ASTM C423. Alpha W 0.55 (class D)-0.95 (class A) per ISO 354/ISO11654.
25 mm: NRC 0.85-0.90 per ASTM C423. Alpha W 0.85 (class B)-0.95 (class A) per ISO 354/ISO11654.
39 mm: NRC 0.85-0.90 per ASTM C423. Alpha W 0,90 – 0.95 (class A) per ISO 354/ISO11654.
Ceiling Attenuation Class (CAC)
15 mm with 50 mm backer board: 51 per ASTM E1414.
Is it really possible? Yes, where there’s a will there’s a way! Contact us and we will share our experience and help you find your best solution for a fantastic seamless acoustic experience. And of course we are happy to send more information or a product sample if requested.